4G Connectivity · Custom Development for Enterprises

4G Water Quality Monitoring Terminal Development

For water quality instrument companies, water integrators and aquatic product monitoring product companies, it can connect pH, dissolved oxygen, conductivity and other instruments to develop collection, cleaning status recording, sensor abnormality prompts, local storage and data reporting.

Environmental monitoring terminal and data systemSoftware, hardware and system integration testingPhased delivery

SERVICE OVERVIEW

Service overview

4G Water quality monitoring terminal development is aimed at enterprise projects with "no fixed network at monitoring points in rivers or aquaculture water bodies". Winge Technology carries out the docking of terminal hardware, embedded software and business systems based on existing equipment and target functions, forming design data and programs that can be used for subsequent integration testing, deployment and maintenance.

  • Device and interface access
  • Product business functions
  • Platform and data connection
  • Exception handling and operational constraints

DEVELOPMENT SCOPE

Development services

Development Scope

01

Device and interface access

Connect to pH, dissolved oxygen, conductivity and other instruments to record range, temperature compensation, calibration status and cleaning status, and unify the data interface.

02

Product business functions

Connect to pH, dissolved oxygen, conductivity and other instruments to develop collection, cleaning status recording, sensor abnormality prompts, local storage and data reporting.

03

Platform and data connection

Combined with the business link of monitoring instruments → status verification and collection → 4G reporting → trend and alarm → maintenance record, the device identity, data fields, update time, abnormal status and result confirmation method are defined.

04

Exception handling and operational constraints

Sensor maintenance and calibration directly affects data availability, and data during cleaning or calibration should be accompanied by status and not mixed with normal statistics.

Data and Operational Workflow

Water quality instrument collection → status filtering → local saving → 4G upload → trend query, maintenance reminder and exception notification.

The device side, communication side and platform side retain necessary status and logs respectively. Project integration testing is checked with actual equipment data and execution results, and network connection status and business completion status are recorded separately.

Project Inputs

  • Existing device models, interface and wiring diagrams, licensing agreements, data samples and available codes.
  • Business processes and parameters: probe interface, dimensions, cleaning calibration status and outlier processing.
  • Target location, operator, SIM/APN, power supply, installation method and equipment size.
  • Existing platform interfaces, user roles, development modules, number of prototypes and planned nodes.

Deliverables and Acceptance

DeliverablesDelivery contentVerification method
product realizationHardware design data, prototypes or existing equipment modification data involved in the project, as well as corresponding firmware and interfacesCheck the instrument original value, compensation value and platform field.
Business integration testingData fields, status definitions, platform adaptation procedures and business integration testing recordsTest the mark after the sensor is disconnected and restored.
Version and test dataTarget hardware and software versions, build or deployment instructions, parameter configurations and test logsVerify records and retransmissions during cleaning and disconnection periods.

First confirm the scope and key functions, then complete prototype or software development, system integration testing and stage acceptance. The acceptance conditions list the prototype, version, environment, duration and passing threshold; source code, design documents, third-party licenses, materials, traffic, cloud resources and on-site work are agreed separately.

Frequently Asked Questions

Can different water quality probes share the same terminal?

It can be evaluated one by one according to the interface and protocol, and the power supply, wiring, address, sampling timing and dimensions need to be checked. Analog probes also need to confirm signal conditioning, sampling accuracy and calibration methods.

Can I entrust only part of the functions of the water quality monitoring terminal?

The device interface, terminal program, 4G communication and platform integration testing can be split based on the existing R&D foundation. Please provide existing data and target boundaries, first check the "probe interface, dimensions, cleaning calibration status and outlier processing", and then clarify the deliverables and interface responsibilities of each module.

How are costs and cycle time assessed?

Split the workload based on target devices, interfaces, existing data, and verification criteria. This project focuses on checking the probe interface, dimensions, cleaning and calibration status, and outlier processing; when prototypes, on-site integration testing, or third-party platform cooperation are required, the corresponding costs, prerequisites, and milestones will be listed separately.

PROJECT DELIVERY

From requirements to delivery

01

Requirements review

Confirm business goals, existing devices and systems, interfaces and deployment conditions.

02

Scope and solution

Review technical dependencies and agree responsibilities, deliverables and acceptance methods.

03

Development and integration

Implement the agreed scope and integrate with the target devices and systems.

04

Testing and issue resolution

Run agreed test cases and record issues, fixes and regression results.

05

Handover and acceptance

Deliver the agreed work, build configurations, interface documentation and test records.

06

Maintenance and changes

Handle version maintenance and assess new requirements within the agreed support scope.

Define Devices, Interfaces and Deliverables

Please provide the target functions, existing equipment information and usage environment of the 4G water quality monitoring terminal, focusing on the probe interface, dimensions, cleaning calibration status and abnormal value processing, so as to facilitate the determination of the technical scope and stage delivery arrangements.

Discuss 4G Development
Online
Phone
13910119357
WeChat
WhatsApp
Winge Technology WhatsApp QR code Scan or click to contact us
Top