LOW-POWER ENGINEERING SERVICES

Low-Power Water, Gas and Heat Metering Solutions

For meter manufacturers and meter reading system integrators, the meter needs to continuously retain measurement data. The communication and execution modules work intermittently most of the time. It provides product solutions, interface development, power consumption management and verification delivery.

business scenarioProduct selectionSystem collaborationProject delivery

SERVICE OVERVIEW

Service Overview

Meters need to continuously retain metering data, and the communication and execution modules work intermittently most of the time. The project design needs to also answer what tasks the device completes, how often it works, how exceptions are handled, and who receives the data.

  • Operating Conditions and Budget
  • Hardware and Firmware
  • Communication and Wake-Up
  • Validation and Delivery

DEVELOPMENT SCOPE

Low-Power Water, Gas and Heat Metering Solutions — Scope

Define the engineering scope, required inputs and validation methods around the power source, operating cycle and response requirements.

Solution Scope

Meters need to continuously retain metering data, and the communication and execution modules work intermittently most of the time. The project design needs to also answer what tasks the device completes, how often it works, how exceptions are handled, and who receives the data.

01

Product and Interface Selection

Combined with the measurement interface, pulse frequency, freezing rules, valve specifications, and entire meter test requirements, choose to collect, control, or record the product form.

02

Power Supply and Operating Strategy

The metering link and the networking link are budgeted separately, and pulse retention, frozen storage and valve action are checked to avoid communication failures affecting metering records.

03

Device and Platform Integration

Clarify the data model, connection facilities, parameter configuration, task confirmation and offline business behavior.

04

Validation and Project Delivery

Write the function, energy consumption and environmental conditions into the test schedule, and deliver the design, procedures and records by product module.

Product Development Services

Product directionBusiness issues and development priorities
Low-Power Smart Water Meter Electronics DevelopmentDistributed water meters need to read automatically to reduce manual meter reading; continuously retain counts, freeze data periodically, and read downstream tasks after waking up communication.
Low-Power Gas Meter Communication and Control Module DevelopmentThe gas meter needs to be connected to the network periodically and the controlled valve is executed; it is connected to the network according to the reading period, the command authority and validity period are verified, and the actual valve status is fed back after execution.
Low-Power Heat Meter Data Acquisition Board DevelopmentThe heat meter needs to complete measurement and periodic data transmission; synchronize collection and accumulation according to measurement requirements, save data in batches, and communicate in the reading window.
Low-Power Pulse Meter Reader DevelopmentInventory instruments need to be collected externally without changing the original measurement core; maintain necessary counting links, save cumulative values periodically, centrally upload and record confirmation status.
Product Development

Low-Power Smart Water Meter Electronics Development

Low-power smart water meter electronic module development services for meter manufacturers and meter reading system integrators. Focusing on the need for automatic reading of distributed water meters and reducing manual meter reading, we develop software and hardware, working status and data interfaces, and verify power consumption and functions according to agreed working conditions.

Explore the Scope
Product Development

Low-Power Gas Meter Communication and Control Module Development

Low-power gas meter communication and control module development services for meter manufacturers and meter reading system integrators. Focusing on the need for periodic networking and controlled valve execution of gas meters, we develop software and hardware, working status and data interfaces, and verify power consumption and functions according to agreed working conditions.

Explore the Scope
Product Development

Low-Power Heat Meter Data Acquisition Board Development

Low-power heat meter acquisition main board development services for meter manufacturers and meter reading system integrators. Based on the needs of heat meters to complete measurement and periodic data transmission, we develop software and hardware, working status and data interfaces, and verify power consumption and functions according to agreed working conditions.

Explore the Scope
Product Development

Low-Power Pulse Meter Reader Development

Low-power pulse meter reading collector development services for meter manufacturers and meter reading system integrators. Focusing on the external collection of existing meters, without changing the original measurement core, we develop software and hardware, working status and data interfaces, and verify power consumption and functions according to agreed working conditions.

Explore the Scope

System Architecture and Operation

The metering link and the networking link are budgeted separately, and pulse retention, frozen storage and valve action are checked to avoid communication failures affecting metering records.

  • Device side: Determine the always-on detection, periodic collection and on-demand execution modules according to the target product.
  • Connector: Determine the receiving node, gateway or public network link, and define the receiving window and disconnection status.
  • Business end: Process records, alarms, configurations and execution acknowledgments according to the customer system.
  • Maintenance end: retain power, exception and version information, arrange local maintenance or remote upgrade.

Project Inputs

  • Metering interface, pulse frequency, freezing rules, valve specifications, and entire meter test requirements.
  • Target equipment quantity, installation method, life cycle and on-site environment.
  • Hardware, program, platform and protocol information are available.
  • Battery or energy constraints, functional delays, and acceptable maintenance practices.

Delivery and Acceptance

Delivery levelContent and verification focus
Product planForm product portfolios, interface boundaries, power supply and communication solutions, accounting for on-site infrastructure dependencies.
Development and implementationThe hardware or firmware, data interface, parameters and joint debugging records will be delivered according to the selected product.
Business verificationThe metering link and the networking link are budgeted separately, and pulse retention, frozen storage and valve action are checked to avoid communication failures affecting metering records, and corresponding functional behaviors and on-site differences are recorded.
Power consumption and maintenanceMeasure typical and abnormal energy consumption in a certain business cycle, check for low battery, loss of connection and recovery, and provide version and maintenance instructions.

Specialist Engineering Services

Choose module development, system integration or testing services based on product foundation to avoid duplication of existing capabilities.

Specialist Engineering

Power Domain and Peripheral Power-Gating Development

Multi-power domain and peripheral power-off control development services, split power domains, design switches, signal isolation and recovery timing, and deliver power trees, timing diagrams, switching circuits, drive and shutdown test records. The scope of the project is determined based on the target equipment, existing data and acceptance conditions.

Explore the Scope
Specialist Engineering

MCU Sleep and Wake-Up Firmware Development

MCU Sleep wake-up firmware development service, develops sleep entry conditions, wake-up determination, clock recovery and driver reconstruction, and delivers state machine, firmware, wake-up timing and function regression records. The scope of the project is determined based on the target equipment, existing data and acceptance conditions.

Explore the Scope
Specialist Engineering

Low-Power State Machine and Fault Recovery Development

Low-power state machine and exception recovery development services, design failure exit, bounded retry, persistence and restart recovery, delivery of state diagrams, code, configuration and fault injection records. The scope of the project is determined based on the target equipment, existing data and acceptance conditions.

Explore the Scope
Specialist Engineering

NB-IoT/LTE-M Power Saving Mode Integration

NB-IoT/LTE-M power saving mode adaptation service, requesting and checking power saving parameters, linking sampling reporting and downlink windows, processing mode is unavailable, delivering module configuration, state machine, network log and corresponding current waveform. The scope of the project is determined based on the target equipment, existing data and acceptance conditions.

Explore the Scope
Specialist Engineering

System Power, Battery Life and Environmental Validation

Complete machine power consumption, battery life and environmental verification services, measuring state current, event energy, peak voltage drop and long-term business operation, delivering original waveforms, logs, calculation sheets, test reports and coverage. The scope of the project is determined based on the target equipment, existing data and acceptance conditions.

Explore the Scope
Specialist Engineering

Battery Power, Charging and State-of-Charge Management

Battery power supply, charging and power management development services, design conversion, charging and protection, determine power estimation and low battery threshold, deliver power circuit, parameter configuration, status interface and load test records. The scope of the project is determined based on the target equipment, existing data and acceptance conditions.

Explore the Scope

Frequently Asked Questions

Does communication module development include entire meter metering certification?

The communication, control and metrology cores should be defined separately in the brief. The measurement performance and applicable certification of the entire meter need to be arranged separately with the complete product.

Does a scenario project have to develop all products simultaneously?

Select the required products according to business processes. The development of low-power smart water meter electronic modules and the development of low-power gas meter communication and control modules can be established separately, and the shared data models or platform interfaces can be unified in the demand stage.

How do I arrange for advance verification?

First select representative points and products, check the measurement interface, pulse frequency, freezing rules, valve specifications, and entire meter test requirements. After verifying key power supply, interfaces, and business links, then determine the development scope of the remaining points and equipment.

PROJECT DELIVERY

From needs assessment to project delivery

Plan each stage around defined inputs, versions, deliverables and acceptance criteria.

01

Requirements Review

Confirm goals, existing infrastructure, interfaces, environment, plans and acceptance conditions.

02

Architecture and Scope

Assess critical links and dependencies, confirm work packages, delivery lists and boundaries.

03

Development and Integration

Implement development according to the baseline and jointly debug item by item on the target system or prototype.

04

Testing and Issue Resolution

Document results and close issues as per agreed versions, environments, inputs and methods.

05

Delivery and Acceptance

Deliver agreed results, build deployment materials, test records and known limitations.

06

Maintenance and Change Control

Handle version maintenance, problem support and new requirements changes according to the scope of the contract.

Discuss Your Low-Power Project

Please provide the metering interface, pulse frequency, freezing rules, valve specifications, entire meter test requirements, and describe the site foundation, equipment quantity, maintenance methods and planned milestones to clarify the product portfolio and development work package.

Discuss Your Project
Online
Phone
13910119357
WeChat
WhatsApp
Winge Technology WhatsApp QR code Scan or click to contact us
Top

PROJECT INTAKE

Submit Project Requirements

Please leave your contact information and project requirements so that the technical staff can confirm the development scope with you.

Local preview: you can complete and validate the form. No message will be sent.

You can also contact us through the following methods

WeChat

Winge Technology WeChat QR code

Use WeChat to scan the QR code to contact

WhatsApp

Winge Technology WhatsApp QR code

Scan the QR code or Click to contact