Development Scope
Device and interface access
Read the concentration, range, fault and calibration status of existing gas detectors, and distinguish measurement data, equipment faults and communication faults.
Product business functions
Adapt to the gas detector protocol, read concentration, range, fault and calibration status, report and notify development events; measurement indicators are verified and determined by the detector and the complete device.
Platform and data connection
Combined with the business link of monitoring instruments → status verification and collection → 4G reporting → trend and alarm → maintenance record, the device identity, data fields, update time, abnormal status and result confirmation method are defined.
Exception handling and operational constraints
Network development does not change the measurement principle or protection level of the detector; deployment in hazardous locations must determine special requirements based on the use conditions of the entire machine.
Data and Operational Workflow
Detector output → terminal data verification → local event record → 4G reporting → enterprise background notification, confirmation and processing.
The device side, communication side and platform side retain necessary status and logs respectively. Project integration testing is checked with actual equipment data and execution results, and network connection status and business completion status are recorded separately.
Project Inputs
- Existing device models, interface and wiring diagrams, licensing agreements, data samples and available codes.
- Business processes and parameters: gas type, calibration status, fault identification and local alarm responsibilities.
- Target location, operator, SIM/APN, power supply, installation method and equipment size.
- Existing platform interfaces, user roles, development modules, number of prototypes and planned nodes.
Deliverables and Acceptance
| Deliverables | Delivery content | Verification method |
|---|---|---|
| product realization | Hardware design data, prototypes or existing equipment modification data involved in the project, as well as corresponding firmware and interfaces | Check gas type, unit and alarm status item by item. |
| Business integration testing | Data fields, status definitions, platform adaptation procedures and business integration testing records | Data processing during test probe failure, warm-up and calibration. |
| Version and test data | Target hardware and software versions, build or deployment instructions, parameter configurations and test logs | Verify event status after notification retry and manual confirmation. |
First confirm the scope and key functions, then complete prototype or software development, system integration testing and stage acceptance. The acceptance conditions list the prototype, version, environment, duration and passing threshold; source code, design documents, third-party licenses, materials, traffic, cloud resources and on-site work are agreed separately.
Frequently Asked Questions
Can on-site alarm be replaced after being connected to the Internet?+
On-site alarm and safety interlocking should operate independently according to the original system responsibilities. 4G is used for remote recording and notification. The project needs to define the local behavior when the connection is lost and the platform's prompt for offline status.
Can I entrust only part of the functions of the gas monitoring data terminal?+
The device interface, terminal program, 4G communication and platform integration testing can be split based on the existing R&D foundation. Please provide existing data and target boundaries, first check "gas type, calibration status, fault identification and local alarm responsibilities", and then clarify the deliverables and interface responsibilities of each module.
How are costs and cycle time assessed?+
Split the workload based on target devices, interfaces, existing data, and verification criteria. This project focuses on checking gas type, calibration status, fault identification and local alarm responsibilities; when prototypes, on-site integration testing or third-party platform cooperation are required, the corresponding costs, prerequisites and nodes will be listed separately.
Online