Test, Assembly and Instrumentation Development

Cold-plate and pipe pressure-hold and flow-resistance test control

Collect pressure differential flow, control the pressure maintaining process and output curves and judgment records Source code, design documents, instrument licensing, procurement, on-site support and ongoing maintenance scope are listed in the project documents.

Equipment condition and scope confirmation

Start with one interface or measurement process, or combine acquisition, control, operator interfaces and data records. Confirm equipment, methods, reference instruments and acceptance conditions before implementation.

Collect pressure differential flow, control the pressure maintaining process and output curves and judgment records

Applicable purchasers

CDU, cold plate, quick connect, liquid cooling cabinet and test equipment supplier

Test and assembly objects

Cold plate, joints and pipeline test pieces

Development and delivery

Collect pressure differential flow, control the pressure maintaining process and output curves and judgment records

Project input

Specimen medium, pressure/vacuum range, volume temperature, reference instrument, flow path and fixture

Acceptance method

Compare the pressure/pressure difference/flow reference under fixed medium, pressure range, volume and temperature to verify the pressure holding process, steady-state flow resistance curve, abnormal termination and repeatability; pressure drop does not directly convert to leakage rate.

Implementation steps

Object and interface verification → Reference link and solution confirmation → Single module prototype → Instrument and equipment joint debugging → Independent reference re-inspection → Source code, configuration and record delivery.

Equipment condition and scope confirmation

The scope may include control boards, firmware, instrument drivers, host software, process configuration and test records. Mechanical fixtures, pressure-bearing structures, fluid circuits, power circuits and optical or acoustic references are provided or separately designed by the responsible parties. Measurement specifications are established through validation with the target equipment and independent references.

Source code, design documents, instrument licensing, procurement, on-site support and ongoing maintenance scope are listed in the project documents.

FAQ

What input conditions are required for this task?

Specimen medium, pressure/vacuum range, volume temperature, reference instrument, flow path and fixture

How to accept this task?

Compare the pressure/pressure difference/flow reference under fixed medium, pressure range, volume and temperature to verify the pressure holding process, steady-state flow resistance curve, abnormal termination and repeatability; pressure drop does not directly convert to leakage rate.

Can I delegate only the instrument interface or test software?

The scope can cover an individual instrument driver, acquisition, process control, data calculation or user-interface module. Complete equipment integration requires separate agreement on mechanical, electrical, method and site responsibilities.

Related services

Provide equipment and test conditions and confirm development scope

Describe the device under test, existing bench, instrument interface, target operating conditions and modules to be delivered.

Communicate project needs
Online
Phone
13910119357
WeChat
WhatsApp
Winge Technology WhatsApp QR code Scan or click to contact us
Top