4G Connectivity · Custom Development for Enterprises

4G Water Telemetry and Control System Development

For water conservancy equipment manufacturers, water operation companies and engineering integrators, it develops on-site terminals, data links and remote management for hydrological telemetry, pumping stations, pipe networks and meter reading projects.

Industry sceneTerminal and platform collaborationDelegate by module

SERVICE OVERVIEW

Service overview

Develop on-site terminals, data links and remote management for hydrological telemetry, pumping stations, pipe networks and meter reading projects. Winge Technology is aimed at water conservancy equipment manufacturers, water operation companies and engineering integrators. It combines acquisition, control, communication and application development based on on-site equipment, business processes and existing systems of the company.

  • Field devices and terminals
  • Business and data
  • Platform and operation and maintenance
  • system constraints

DEVELOPMENT SCOPE

Development services

Scenario development scope

01

Field devices and terminals

Focus on 4G hydrological telemetry RTU development, 4G pumping station monitoring terminal development and other products to clarify the interface, power supply and installation conditions, and develop or transform terminals.

02

Business and data

Define data, events, commands and results according to water level, rainfall and meter → RTU or monitoring terminal → 4G → Water Platform → Duty and Maintenance, and retain the association between equipment, sites or projects.

03

Platform and operation and maintenance

Connect with existing enterprise platforms, or develop device management, historical data, alarms, permissions and client functions, and determine the scope by module.

04

system constraints

In the planning stage, check the telemetry protocol version, site power supply, underground communication, pump station interlocking and metering caliber, and clarify the responsibilities and exception handling of local and remote systems.

product development services

Select corresponding technical services based on field equipment and target business. You can start with a single terminal or combine multiple device types. The following products describe the interfaces, business processes, delivery materials and acceptance methods respectively.

Product Development

4G Hydrological Telemetry RTU Development

For hydrological equipment companies, water conservancy integrators and monitoring platform companies, it is connected to water level and rainfall equipment, and develops scheduled reporting, event reporting, clock management, telemetry protocol adaptation and low battery processing.

View Development Scope and Deliverables →
Product Development

4G Pump Station Monitoring Terminal Development

For pump station equipment manufacturers, water operators and control system integrators, it collects liquid level, pressure, pump status and faults, and develops control permissions, command acknowledgments, local interlocking interfaces and platform monitoring.

View Development Scope and Deliverables →
Product Development

4G Pipeline Level and Manhole Cover Monitoring Terminal Development

For pipe network monitoring equipment companies, municipal integrators and facility operating units, it can access liquid level, cap opening or tilt detection, and develop event wake-up, hierarchical reporting, power management, equipment maps and inspection records.

View Development Scope and Deliverables →
Product Development

4G Remote Meter Reading Data Collector Development

For meter manufacturers, energy consumption platform companies and meter reading system integrators, it adapts to pulse or serial meter protocols and develops reading collection, magnification conversion, time freezing, re-reading and usage statistics.

View Development Scope and Deliverables →

System composition and business process

Water level, rainfall and meter → RTU or monitoring terminal → 4G → Water affairs platform → Duty and maintenance.

The platform manages devices according to enterprise projects, sites and permissions. After the link is restored, check the data and service status; when control is involved, separately confirm command authority, timeliness, local conditions and execution feedback.

Project Inputs

  • Target business, equipment list, on-site location, equipment size and users.
  • Wiring, protocols, raw data and open software interfaces to existing equipment.
  • Key points to confirm: telemetry protocol version, site power supply, underground communications, pumping station interlocking and metering caliber.
  • Platform status, data retention, client and deployment methods, prototype and on-site verification conditions.

Deliverables and Acceptance

stageDelivery contentVerification basis
Needs and plansEquipment interface list, business process, system architecture and development division of laborVerify telemetry protocol versions, site power supplies, underground communications, pump station interlocks, and metering calibers.
Development and integration testingAgree on terminal hardware, firmware, interfaces and platform applicationsCheck the fields, status, instructions and abnormal behaviors one by one according to the actual device.
Acceptance and handoverPrototype or program, design and deployment data, test records and version listAccept according to the agreed environment, sample, duration and threshold, and record the handling of failed items.

R&D, prototype materials, structure, testing, on-site implementation and subsequent operation and maintenance are listed separately. Project cost and cycle are evaluated based on equipment type, interface complexity, existing foundation and verification workload.

Specialist Development Services

Existing products or internal R&D teams can only entrust the following technical links. The interface and integration testing responsibilities are clearly stated in the project documents.

Specialist Development

4G Battery and Solar Power System Development

For battery terminal manufacturers and outdoor equipment R&D teams, we develop charging, power conversion, peak power supply, power detection and sleep control; deliver circuits, power consumption state design, battery life estimation and measurement records.

View Development Scope and Deliverables →
Specialist Development

4G Modbus Data Acquisition and Protocol Conversion Development

For instrumentation companies, industrial equipment manufacturers and system integrators, develop RTU/TCP device polling, byte order and scaling, platform field mapping and write acknowledgments; deliver mapping tables, source code and message records.

View Development Scope and Deliverables →
Specialist Development

4G Offline Buffering and Resumable Data Upload Development

For monitoring terminal enterprises and data gateway R&D teams, develop persistent queues, serial numbers, confirmations, deduplication, speed limits and capacity overflow strategies; deliver cache modules, parameter descriptions and network and power outage records.

View Development Scope and Deliverables →
Specialist Development

4G Remote Command and Execution Acknowledgment Development

For networked control equipment companies and platform R&D teams, develop command identification, permissions, validity period, idempotence, execution status and result acknowledgments; deliver command specifications and verification records such as timeout, duplication, loss of contact, etc.

View Development Scope and Deliverables →

Frequently Asked Questions

How to divide the scope of monitoring and remote control?

The monitoring side clarifies readings, events and records, and the control side adds permissions, validity period, local interlocking and execution feedback. The protection and disconnection behavior of pumping stations and other equipment are confirmed in the system design stage.

Can I reuse existing platforms and terminals?

You can first check the existing interfaces, data and code, and focus new development on the missing links. In this scenario, it is necessary to focus on checking the telemetry protocol version, site power supply, underground communication, pumping station interlocking and metering caliber, and then determine the reusable range and return work.

PROJECT DELIVERY

From requirements to delivery

01

Requirements review

Confirm business goals, existing devices and systems, interfaces and deployment conditions.

02

Scope and solution

Review technical dependencies and agree responsibilities, deliverables and acceptance methods.

03

Development and integration

Implement the agreed scope and integrate with the target devices and systems.

04

Testing and issue resolution

Run agreed test cases and record issues, fixes and regression results.

05

Handover and acceptance

Deliver the agreed work, build configurations, interface documentation and test records.

06

Maintenance and changes

Handle version maintenance and assess new requirements within the agreed support scope.

Define Devices, Interfaces and Deliverables

Please provide the business process, target equipment and existing system information, and describe the telemetry protocol version, site power supply, underground communication, pump station interlocking and metering caliber to facilitate the formation of product portfolio, work division and stage delivery arrangements.

Discuss 4G Development
Online
Phone
13910119357
WeChat
WhatsApp
Winge Technology WhatsApp QR code Scan or click to contact us
Top