4G Water Leak Alarm Terminal Development

For water leakage detection equipment manufacturers, computer room integrators and property operation companies, it adapts point or line water detection interfaces and develops alarm confirmation, disconnection detection, area numbering, notification strategies and processing records.

Alarm and help and Internet radioSoftware, hardware and system integration testingPhased delivery

SERVICE OVERVIEW

Service overview

4G The water leakage alarm terminal is developed for enterprise projects that require remote detection of water leakage in computer rooms and warehouses. Winge Technology carries out the docking of terminal hardware, embedded software and business systems based on existing equipment and target functions, forming design data and programs that can be used for subsequent integration testing, deployment and maintenance.

  • Device and interface access
  • Product business functions
  • Platform and data connection
  • Exception handling and operational constraints

DEVELOPMENT SCOPE

Development services

Development Scope

01

Device and interface access

Adapted to point probes or water leakage detection lines, setting area, probe status, disconnection detection and local prompt interface.

02

Product business functions

Adapt to point or line water detection interfaces and develop alarm confirmation, disconnection detection, area number, notification strategy and processing records.

03

Platform and data connection

Combined with the business link of on-site events or broadcast tasks → local status processing → 4G → enterprise platform → acknowledgment and response records, the device identity, data fields, update time, abnormal status and result confirmation method are defined.

04

Exception handling and operational constraints

The ability to identify water leakage areas is determined by the probe or controller; the communication terminal should not interpret line faults as normal and no leakage.

Data and Operational Workflow

Water leakage or disconnection event → regional positioning → local alarm → 4G notification → manual confirmation and recovery record.

The device side, communication side and platform side retain necessary status and logs respectively. Project integration testing is checked with actual equipment data and execution results, and network connection status and business completion status are recorded separately.

Project Inputs

  • Existing device models, interface and wiring diagrams, licensing agreements, data samples and available codes.
  • Business process and parameters: water detection interface, area number, disconnection identification and notification confirmation rules.
  • Target location, operator, SIM/APN, power supply, installation method and equipment size.
  • Existing platform interfaces, user roles, development modules, number of prototypes and planned nodes.

Deliverables and Acceptance

DeliverablesDelivery contentVerification method
product realizationHardware design data, prototypes or existing equipment modification data involved in the project, as well as corresponding firmware and interfacesTest leakage, disconnection and normal status respectively.
Business integration testingData fields, status definitions, platform adaptation procedures and business integration testing recordsVerify area number with actual wiring.
Version and test dataTarget hardware and software versions, build or deployment instructions, parameter configurations and test logsVerify recurring triggers, notification acknowledgments, and recovery events.

First confirm the scope and key functions, then complete prototype or software development, system integration testing and stage acceptance. The acceptance conditions list the prototype, version, environment, duration and passing threshold; source code, design documents, third-party licenses, materials, traffic, cloud resources and on-site work are agreed separately.

Frequently Asked Questions

Will it be mistakenly judged as normal after the water leakage detection line is disconnected?

Disconnection status identification should be designed according to the detector interface, and water leakage, line failure and normal status should be recorded respectively. If the original probe does not support disconnection identification, you need to first confirm the detection circuit that can be added or replace the interface solution.

Can I entrust only part of the functions of the water leak alarm terminal?

The device interface, terminal program, 4G communication and platform integration testing can be split based on the existing R&D foundation. Please provide existing information and target boundaries, first check the "water detection interface, area number, disconnection identification and notification confirmation rules", and then clarify the deliverables and interface responsibilities of each module.

How are costs and cycle time assessed?

Split the workload based on target devices, interfaces, existing data, and verification criteria. This project focuses on checking the water exploration interface, area number, disconnection identification and notification confirmation rules; when prototypes, on-site integration testing or third-party platform cooperation are required, the corresponding costs, prerequisites and nodes will be listed separately.

PROJECT DELIVERY

From requirements to delivery

01

Requirements review

Confirm business goals, existing devices and systems, interfaces and deployment conditions.

02

Scope and solution

Review technical dependencies and agree responsibilities, deliverables and acceptance methods.

03

Development and integration

Implement the agreed scope and integrate with the target devices and systems.

04

Testing and issue resolution

Run agreed test cases and record issues, fixes and regression results.

05

Handover and acceptance

Deliver the agreed work, build configurations, interface documentation and test records.

06

Maintenance and changes

Handle version maintenance and assess new requirements within the agreed support scope.

Define Devices, Interfaces and Deliverables

Please provide the target functions, existing equipment information and usage environment of the 4G water leakage alarm terminal, focusing on the water detection interface, area number, disconnection identification and notification confirmation rules, so as to facilitate the determination of the technical scope and stage delivery arrangements.

Discuss 4G Development
Online
Phone
13910119357
WeChat
WhatsApp
Winge Technology WhatsApp QR code Scan or click to contact us
Top